install: add time check and warning
Clock skew can cause problems with SSL and certificates. Check the UPS clock and log a warning for the user if the UPS clock is more than 1 hour different than the clock of the system this tool is running on see: https://github.com/gregtwallace/apc-p15-tool/issues/11#issuecomment-2609010943
This commit is contained in:
parent
1cfd35c4e2
commit
47b964d6ee
2 changed files with 68 additions and 0 deletions
pkg/app
|
@ -12,6 +12,8 @@ import (
|
|||
"time"
|
||||
)
|
||||
|
||||
const timeLoggingFormat = time.RFC1123Z
|
||||
|
||||
// cmdInstall is the app's command to create apc p15 file content from key and cert
|
||||
// pem files and upload the p15 to the specified APC UPS
|
||||
func (app *app) cmdInstall(cmdCtx context.Context, args []string) error {
|
||||
|
@ -75,6 +77,16 @@ func (app *app) cmdInstall(cmdCtx context.Context, args []string) error {
|
|||
}
|
||||
app.stdLogger.Println("install: connected to ups ssh, installing ssl key and cert...")
|
||||
|
||||
// check time - don't fail it time is no good, just do logging here
|
||||
upsT, err := client.GetTime()
|
||||
if err != nil {
|
||||
app.errLogger.Printf("warn: install: failed to fetch UPS time (%s), you should manually verify the time is correct on the UPS", err)
|
||||
} else if upsT.After(time.Now().Add(1*time.Hour)) || upsT.Before(time.Now().Add(-1*time.Hour)) {
|
||||
app.errLogger.Printf("warn: install: UPS clock skew detected (this system's time is %s vs. UPS time %s", time.Now().Format(timeLoggingFormat), upsT.Format(timeLoggingFormat))
|
||||
} else {
|
||||
app.stdLogger.Printf("install: UPS clock appears correct (%s)", upsT.Format(timeLoggingFormat))
|
||||
}
|
||||
|
||||
// install SSL Cert
|
||||
err = client.InstallSSLCert(keyP15, certPem, keyCertP15)
|
||||
if err != nil {
|
||||
|
|